【廣告】
混流泵
3、安裝基礎(chǔ):要求土質(zhì)堅實牢固。
4、水泵安裝時,必須保證泵軸的水平位置。
5、進水管末端應(yīng)浸入水平面以下一米左右,但須離開泥底半米左右。
6、水泵安裝好后,計算允許吸上高度和揚程,在水位穩(wěn)定的條件下,要求為規(guī)定數(shù)量值的0.8~1.2倍范圍,否則水泵不會正常運行
I.
Installation Principle
1. Installation
Height: Cidering the height according to the rainy season or dry season.The suction
vacuum
height can
not be higher than the adsorbing height.
2. Installation
Location:The location is better to close to the water source as p as
can.It should be not
only
keeping the safety but also shortening the water inlet pipe and reduce the
headloss
3、水泵出水量不足
The waer yield
of water is not enough
1、進水管路或葉輪有水草雜物
2、轉(zhuǎn)速過低
3、輸水高度過高
4、泵蓋及葉輪磨損間隙過大
5、填料進氣
6、馬力不足
7、進水管口插入水中深度不夠
1. There are waterweeds and sundries in
inlet pipes or impeller
2.The rotate speed is too low
3.Water delivery height is too high
4.The attrition gap between pump cover
and impeller is too large
5.The padding is air in
6.The horsepower is not engough
7.The depth of inlet pipe under water is
not enough
1、清除水草雜物
2、調(diào)整轉(zhuǎn)數(shù)
3、降低輸水高度
4、用紙墊調(diào)整間隙至正常
5、壓緊或更換填料
6、加大馬力
7、增加插入水中深度至一米左右
1.Clear the waterweeds and sundries
2.Ajust the rotate speed
3.Reduce the water delivery height
4.Add paper washers to adjust the gaps
5.Compact or change padding
6.Increase the horsepower
7.Make the depth of inlet pipe under
water to one meter